¡Sale!

Optómetra móvil Plusoptix S12C

El precio original era: $5,995.00.El precio actual es: $3,995.00.

Discover the portable and user-friendly Plusoptix S12C Mobile Vision Screener, a worldwide favorite for quick, accurate vision screening in patients of all ages. Enhance your practice efficiency and detect potential eye issues early.

En stock

Descripción

El Optómetra móvil Plusoptix S12C is a modern device. It quickly and accurately finds common vision problems in patients of all ages.

This portable screener makes vision screening easier. Useful for both local clinics and global healthcare facilities. It also improves patient care around the world.

The designers created the Plusoptix S12C Mobile Vision Screener for use in different exam rooms. You can also use it in various locations. You can document measurement results electronically or on paper.

Plusoptix vision screeners help check for vision problems in children. They can find issues like refractive error, anisocoria, and strabismus.

These screenings can start for kids as young as 6 months old. Because they are so easy to use, pediatricians and school nurses use them alike.

You can perform vision screening on any child. The only requirement is for the child to look at the camera briefly. A specially designed sound target, called a “warble” sound, provokes this fixation.

 

Características principales

 

  • Designed to be used at different locations within the same building (optional carrying case is available)
  • Funciona con pilas recargables de tamaño AA estándar (funciona mientras se carga)
  • Provides in-built patient database for up to 100,000 entries for follow-up management and studies
  • Guarda informes de cribado en la tarjeta SD
  • Can be connected to a DHCP network server using a WLAN connection for CSV data exchange (EMR) and screening report printing
  • Prints self-adhesive labels for documentation in paper records (optional printer required)
  • Garantía sin problemas de un año y actualizaciones de software continuas y gratuitas.
  • Award-winning child-friendly design

 

Plusoptix_S12C_banner

Dispositivos de cribado Plusoptix

La gama de dispositivos Plusoptix S12 detecta errores de refracción y desalineación ocular, ¿cuáles son las causas más comunes de ambliopía (ojo vago)?.

Measurements are non-invasive, requiring no physical contact with the child. A sound target attracts fixation, and no further cooperation is required to perform a measurement.

Características

 

  • Lecturas binoculares
  • Measurement results are compared to age specific thresholds and a “Pass” or “Refer” vision screening result is displayed.
  • Medición desde 1 m de distancia hasta el niño
  • Medición en menos de un segundo
  • Se puede usar en pupilas no dilatadas
  • Función completamente automatizada
  • Los niños pueden ser medidos a partir de los 6 meses de edad
  • La medición es delegable y puede ser realizada fácilmente por un asistente capacitado.
  • Diseño apto para niños
  • Posibilidad de medir sobre gafas y lentes de contacto

The measuring principle is based on eccentric photoretinoscopy: infrared light is projected through the pupils onto the retina. The reflected light forms a specific brightness pattern within the pupil depending on the refractive error. The spherical refraction is calculated based on this crescent pattern.

To determine cylinder and axis, the exact measurement is repeated in three meridians. The measurement with infrared light is entirely innocuous. Infrared light is also contained in daylight and not visible.

Resultados de la detección

Los dispositivos de cribado visual Plusoptix proporcionan valores de medición fiables de:

  • Refracción (equivalente esférico)
  • Diámetro de la pupila y distancia pupilar
  • Simetría de los reflejos corneales

Con estos valores de medición es posible detectar los siguientes trastornos visuales infantiles más prevalentes que pueden provocar el desarrollo de ambliopía (ojo vago), entre ellos:

  • Hipermetropía (visión de lejos)
  • Miopía
  • Astigmatismo (visión borrosa)
  • Anisometropía (poder refractivo desigual)
  • Anisocoria (tamaño desigual de las pupilas)
  • Estrabismo (desalineación de los ojos)

Con los valores de medición determinados comparados con los umbrales específicos para la edad, se muestra un resultado de cribado visual de “Pasa” o “Derivar”. Los niños con un resultado de “Derivar” deben ser enviados a un profesional de la visión para un examen ocular.

¿Cómo se ve un informe de selección? Haz clic aquí para obtener detalles Descripción del informe de cribado de Plusoptix.

plusoptiX-S12C-screening

Why Healthcare Providers Worldwide Must Use the Plusoptix S12C Mobile Vision Screener

  1. Early Detection of Vision Issues
  2. Finding refractive errors or eye problems early is important for effective treatment. This is especially true for children, as their vision affects their development.
  3. Efficient Screening Process
  4. Rapid measurement capabilities reduce bottlenecks in your practice, improving patient flow and increasing overall productivity on a global scale.
  5. Enhanced Patient Engagement
  6. The device is non-invasive and friendly for children. This helps reduce patient anxiety. It encourages positive interactions and builds trust in your practice.
  7. Versatility in Different Environments
  8. The Plusoptix S12C Mobile Vision Screener works well in both rural outreach programs and large urban clinics. It easily adapts to different healthcare facilities around the world.
  9. Cost-Effective Investment
  10. This mobile screener makes screenings easier and reduces extra testing equipment. It provides long-term savings and a fast return on investment.

Specifications / Technical Data

  • EMR interface & Patient database
  • Informe tamaño carta y etiqueta autoadhesiva
  • plusoptiXconnect compatibility
  • WLAN interface
  • Fuente de alimentación: 6 pilas AA recargables
  • Touchscreen operation: 5.7 Inch (capacitive)
  • Weight: 35.3 oz (1.0 kg)
  • Interfaces: 2 x USB, IR, SD, WLAN
  • Tecnología de Medición: Retinoscopia fotográfica infrarroja binocular con iluminación única de 54 LED
  • Rango de medida: -7.00 a +5.00 dpt en incrementos de 0.25 dpt
  • Tamaño de la pupila: 4.0 a 8.0 mm en incrementos de 0.1 mm
  • Certificaciones: FDA (EE. UU.), Health Canada (Canadá), CE (Europa)
  • Garantía: Garantía sin complicaciones de 1 año (solo EE. UU., Canadá y UE; hay extensiones disponibles para la compra)
  • Actualizaciones de software: gratuitas (descargables desde nuestro sitio web)
  • Costo operativo: No necesita calibración ni mantenimiento
  • (Exact specifications may vary; consult official Plusoptix documentation for detailed technical information.)

Vision Screener Device Model Comparison

All Plusoptix Binocular Autorefractors share the same measurement technology and algorithm. Hence, measurement accuracy is identical across all available device models. The devices differ in mobility and documentation options as specified below.

Estacionario in one exam roomMobile between multiple exam rooms or locations

Vision Screener plusoptiX S16
plusoptiX-S12C-in-comparison-with-ball
Vision Screener plusoptiX S12C
plusoptiX-S12R-in-comparison-with-ball
Vision Screener plusoptiX S12R
Letter-size report& self-adhesive labelyes / yesyes / yesyes / yes
LAN / WIFI interfaceyes / yesno / yesno / no
Connection to EMR / plusoptiXconnectyes / yesyes / yesno / no
External monitor interfaceyes (DVI)nono
Power supplyMedical power adapter
(100 – 240 V AC / 50 – 60 Hz)
6x rechargeable batteries
(Standard AA size)
6x rechargeable batteries
(Standard AA size)
Hardware Features
Touchscreen operation4.3 Inch (resistive)5.7 Inch (capacitive)4.3 Inch (resistive)
Peso26.5 oz (0.75 kg)35.3 oz (1.0 kg)28.2 oz (0.8 kg)
Interfaces4 x USB, IR, DVI, LAN (RJ-45), WLAN2 x USB, IR, SD, WLAN2 x USB, IR, SD
Identical Features
Measurement TechnologyBinocular infrared photo retinoscopy with unique 54 LED illumination
Rango de medida-7.00 to +5.00 dpt in 0.25 dpt increments
Pupil Size3.0 to 8.0 mm in 0.1 mm increments
Acquisition timedynamic, in average 0.5 sec.
Measuring distance3.3 ft ± 2 in (1 m ± 5 cm)
Fixation targetWarble sound and Smiley face
Certificación
Service Features
GarantíaHassle-free warranty (can be extended for a period of up to 10 years after initial commissioning)
Operating CostNone, because no calibration or maintenance is needed

Incluir:

Plusoptix S12C vision screener, plusoptiX S12C & S12R – P12 Label Printer (Only), plusoptiX S12C/S12R/S16 Carrying Case, neck strap, 4 GB SD card, 6 rechargeable “AA” batteries, 2 year hassle-free warranty, and a medical power adapter.

Preguntas frecuentes

  1. Q: Is the Plusoptix S12C Mobile Vision Screener suitable for exceptionally young children?
  2. A: Yes. The device can screen children as young as six months, making it ideal for early detection of vision problems.
  3. Q: Does this device require frequent calibration?
  4. A: The screener comes factory-calibrated. Experts recommend periodic checks, but they typically do not require extensive manual calibrations.
  5. Q: Can I integrate this screener with my existing Electronic Medical Records (EMR) system?
  6. A: Yes. The Plusoptix S12C Mobile Vision Screener can transfer data using USB or Wi-Fi. This makes it easy to connect with many EMR systems around the world.
  7. Q: How do I maintain the device to ensure accuracy over time?
  8. A: Clean and store the device according to the manufacturer’s guidelines. Keeping it charged and updated with the latest software will help maintain accuracy.
  9. Q: Is there a warranty for the Plusoptix S12C Mobile Vision Screener?
  10. A: Yes, Plusoptix provides a warranty. Specific terms may vary by region, so consult your local distributor or the manufacturer for more details.

Referencia