Sale!
 

iCare ST500 Slit-lamp Tonometry

Original price was: $5,150.00.Current price is: $3,150.00.

Discover the iCare ST500 Slit-Lamp Tonometer for precise intraocular pressure (IOP) measurements and comprehensive eye examinations. Enhance your clinic with this integrated, user-friendly diagnostic tool today!

In stock

SKU: iCare ST500 Category: Tag:
 

Description

The iCare ST500 Slit-Lamp Tonometer represents a significant advancement in ophthalmic diagnostic technology, seamlessly integrating tonometry with slit-lamp examination. Designed by iCare, a renowned leader in eye care equipment, the ST500 offers eye care professionals a versatile and efficient tool for accurate intraocular pressure (IOP) measurement alongside detailed anterior segment analysis.

This integration enhances diagnostic capabilities, streamlines workflows, and improves patient outcomes in glaucoma management and overall eye health assessment.

“iCare ST500 brings the key elements of the iCare rebound technology within the slit-lamp based tonometry laid the foundations of a new era in the slit-lamp based tonometry market,”  “We’re excited to offer another great option to help eye care practitioners acquire and monitor patients’ eye intraocular pressure.”

Daniele Mantovano, iCare’s Global Business Line Director

iCare ST500, the world’s first slit lamp-mounted rebound tonometer, makes measuring intraocular pressure easy, quick and accurate — and comfortable for patients. With the ST500, a new era in slit lamp tonometry* has begun.

 

iCare ST500 Key features

  • Fast, accurate, and repeatable IOP measurements
  • Intuitive user interface, available in multiple languages
  • Universal adapter for most slit lamps with 8 mm focus rod mount hole
  • Harmless and barely noticeable momentary contact
  • Stable patient positioning for easier measurement
  • Easy probe insertion with an applicator
  • SmartCradle for charging and storing the device
  • Can be operated with an optional handheld remote control
  • Quick Measure mode for challenging IOP measurements
  • Disposable probes: no need for disinfection between patients

A new era in slit lamp tonometry

Clinical validation of the iCare ST500 indicates a high agreement of IOP measurements to Applanation Tonometry. With minimal training, repeatable and accurate measurements will be captured independent of operator skill.

An eye for value creation

Improving patient experience is a crucial step towards human-centered care and value creation in terms of efficiency, quality, and customer loyalty. Using the iCare ST500 improves both office efficiency and patient management the moment the examination begins.

iCare_ST500_in_slitlamp_close_up

Designed for slit lamp use

The iCare ST500 makes IOP measurement an integral part of standard slit lamp use. It’s compatible with the majority of the most common slit lamps with an 8 mm focus rod mounting hole. Probe installation is easy with the provided applicator. The SmartCradle houses an adapter for the tonometer, probe applicator, probe box, and an optional remote control. The ST500 can be conveniently paired with a Bluetooth printer.

iCare_ST500_man_measuring_screen_showing

Optimal workflow: time-savings, accuracy, and comfort

The iCare ST500 ensures clinical workflow, efficiency, and patient comfort. Due to our rebound technology, the patients barely notice the measurement. The device removes the need for topical anesthesia, fluorescent dye, disinfection, or calibration. The gentle rebound touch of a disposable probe makes the acquisition barely noticeable to the patient, with no harm to the cornea or impact on later diagnostics.

iCare_ST500_doctor_woman_measuring_white_background

Quick Measure — a faster way to measure IOP

The Quick Measure mode requires only two or three rapid individual measurements instead of the standard six, resulting in a shorter test time. This faster way to measure is particularly beneficial in challenging measuring situations. Repeatable and accurate measurements are captured effortlessly.

iCare_ST500_woman_measuring_closeup

Reliability for every measurement

The iCare ST500’s calibration-free rebound technology, combined with the slit lamp-mounted design that optimizes patient positioning, eliminates subjectivity. You get accurate, repeatable, and prompt IOP results — ensuring unparalleled patient experience and workflow. The results are shown with precise digital numbers on the screen. Due to the disposable probes, there is no need for time-consuming disinfection and sterilization procedures between patients.

iCare_ST500_doctor_man_measuring

How the iCare ST500 Slit-Lamp Tonometer Works

The iCare ST500 Slit-Lamp Tonometer operates by integrating two essential diagnostic tools into one cohesive system:

  1. Rebound Tonometry:
  • A lightweight, disposable probe is propelled towards the cornea.
  • The device measures the deceleration and rebound pattern of the probe to calculate the intraocular pressure accurately.
  • This method eliminates the need for contact time and anesthetic drops, making the process swift and comfortable.
  1. Slit-Lamp Examination:
  • Utilizes high-definition LED lighting and adjustable magnification to provide detailed views of the anterior segment.
  • Clinicians can switch between filters and illumination settings to examine ocular structures and identify abnormalities.

Combining these functionalities, the ST500 allows for simultaneous IOP measurement and comprehensive anterior segment evaluation, enhancing diagnostic accuracy and efficiency.

Use Cases

  • Ophthalmology Clinics: Ideal for routine glaucoma screenings, comprehensive eye examinations, and detailed anterior segment analysis.
  • Optometry Offices: They are a standard tool for checking eye health. They help monitor eye pressure and manage patients with high eye pressure.
  • Research Institutions: Facilitates accurate data collection for studies on glaucoma, ocular biomechanics, and anterior segment diseases.
  • Mobile Eye Care Services: These devices are more significant than handheld ones but still portable. They are great for mobile clinics that need space-efficient equipment.
  • Teaching Hospitals: Provides a versatile tool for training ophthalmology and optometry students in tonometry and slit-lamp techniques.

Why Choose the iCare ST500 Slit-Lamp Tonometer?

The iCare ST500 Slit-Lamp Tonometer is unique among eye diagnostic devices. It combines tonometry and slit-lamp examination in a new way. This fusion not only enhances diagnostic capabilities but also offers significant practical benefits to eye care professionals:

  • Precision and Reliability: Advanced rebound tonometry ensures accurate IOP measurements for early glaucoma detection and effective management.
  • Comprehensive Assessment: The high-resolution slit lamp provides a clear view of the front part of the eye. This helps diagnose many eye conditions, not just glaucoma.
  • Efficiency and Convenience: Streamlined workflow reduces examination time, enabling clinicians to serve more patients without compromising quality.
  • Cost-Effectiveness: Using two diagnostic tools in one device reduces equipment costs. This also reduces the need for multiple machines, giving a great return on investment.
  • Enhanced Patient Care: Faster, more comfortable examinations lead to higher patient satisfaction and better compliance with regular eye check-ups.

iCare ST500 Slit-Lamp TonometerConclusion

The iCare ST500 Slit-Lamp Tonometer is a new device that improves eye care. It combines accurate pressure measurement with a close look at the front part of the eye. Its advanced technology, user-centric design, and comprehensive functionality make it an indispensable tool for modern ophthalmology and optometry practices.

By investing in the iCare ST500, eye care professionals can improve diagnosis and work more efficiently. This leads to better patient care and helps achieve better eye health outcomes.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.