Description
The ZEISS i. Profiler Plus is an advanced diagnostic tool that revolutionizes how eye care professionals in evaluate vision. This advanced device uses wavefront technology to give accurate measurements. This helps you create custom eyeglass and contact lens prescriptions for patients.
Whether you run a small practice or a large-scale optical center, the ZEISS I. Profiler Plus makes your work easier. It also improves patient experience and satisfaction.
With i.Profiler Plus, you receive a detailed prescription. You also gain access to personalized lenses that enhance color, contrast, and night vision. It is a 4-in-1 system with an ocular wavefront aberrometer, auto refractometer, ATLAS corneal topographer, and keratometer.
The Zeiss I-Profiler Plus creates an exact prescription. Like a fingerprint, it is accurate to 1/100th of a dioptre.
Ever thought that your twilight or night vision poor, ‘worse than daytime’. Combine this with glare from headlights and road signs and night vision can be highly stressful. In low light, pupils get more significant to let in more light. Different parts of the cornea help us see better in these conditions.
Zeiss I-Profiler Plus Key Features:
- Capture, evaluate and explain the best possible solution for each patient
- Provides a comprehensive overview of patients’ visual performance and eye conditions
- Fast, comprehensive and accurate
- Can be incorporated into a digital workstream
- Access to i.Scription® Technology by ZEISS for improved day and night vision
Assist with finding and explaining the best possible solution for each patient.
- ZEISS i.Profiler plus features a high-resolution wavefront measurement and corneal topography, providing you with all the necessary data to evaluate the refractive status of your patient’s eyes fully.
- The analysis mode lets you visualise the impact of different aberrations on your patient’s vision, including up to 7 Zernike aberrations.
- It lets you prescribe ZEISS Lenses with i.Scription Technology uses the generated ‘fingerprint’ measurement of each eye.
- Connectivity to the optional ATLAS Review for ZEISS i.Profiler Plus software enables advanced keratometry and contact lens fitting.
Gives a comprehensive overview of a patient’s visual performance and eye conditions.
- Ability to provide data to support identification and analysis of ocular pathologies or abnormalities.
- Supports the user in identifying patients as promising candidates for ZEISS i.Scription lenses.
- Provides full analysis of the eye’s refractive power distribution across the entire pupil aperture, not just the central zone.
Fast, comprehensive and accurate.
- Fully-automated measurement procedure.
- Touch screen control enables all measurements of both eyes in 60 seconds.
- High-resolution Hartmann-Shack wavefront sensor measuring 1500 points across a 7-millimeter pupil aperture.
- User-friendly, easy-to-use functions enable capture, evaluation, presentation and analysis of data.
- 50% reduction in chair time for subjective examination, due to accurate starting data generated by ZEISS i.Profiler plus.
Access to i.Scription® Technology by ZEISS.
- The 7 visual optics analysis parameters summarize and evaluate the interactions of measurements obtained from the wavefront analyser, the detected pupil and the corneal topographer.
- This provides an automatic and complete assessment of the eye optics, a sound foundation of a fast and accurate subjective refraction, and the identification of ‘i.Scription ready’ patients.
- With ZEISS i.Scription Technology, you can offer each patient a unique lens solution, improving their vision day and night.
- The benefits of i.Scription® Technology by ZEISS can be simulated and demonstrated to the patient using the point spread function graphs and comparison (with and without i.Scription).
Outstanding connectivity: incorporate it into your digital workstream.
- Ability to remotely access the ZEISS i.Profiler plus via VISUCONSULT 500 and demonstrate the patient’s ZEISS i.Scription analysis on the iPad® 2.
- The data captured from the ZEISS i.Profiler plus is saved on the VISUCONSULT 500 data management system, allowing for future consultation use, ordering and archiving, without further measurements.
- It integrates with compatible PMS systems for a smooth and efficient workflow.
ZEISS i.Profiler plus
Technical specifications
Technical Data Wavefront | |
---|---|
Measuring range, cylinder: | 0 D to +8 D |
Measuring range, sphere: | -20 D to +20 D (3.5 mm pupils) |
-15 D to +15 D (5.5 mm pupils) | |
Axis: | 0º – 180º |
Measuring surface: | 2.0 mm to 7.0 mm (three zones) |
No. of measuring points: | up to 1500 |
Method: | Hartmann-Shack |
Reference wavelength1: | 555 nm according to ISO 24157 |
Technical Data Corneal Topography | |
---|---|
No. of rings: | 22 (18 complete rings) |
No. of measuring points: | 3,425 |
Detected corneal surface at 42.125 D: | dia. 0.75 mm to 8.6 mm |
Diopters: | measuring range 25 to 65 D |
Accuracy: | ± 0.05 D (±0.01 mm) |
Reproducibility: | ± 0.10 D (±0.02 mm) |
Type A: | according to ISO 19980 |
Line voltage | 100-240 V AC ± 10%, 50…60 Hz |
---|---|
Power consumption | ≤ 200 VA |
Dimensions (W x H x D) | 345 x 555 x 525 mm |
Weight | 30 kg |
Interfaces | VGA, 3x USB, RS232, 2x LAN |
Printer | Thermal, integrated |
Display | 12″ Color Touch LCD |
Why Eye Care Professionals Must Use the ZEISS i.Profiler Plus
- Accurate Prescriptions
- The device’s in-depth readings ensure your patients receive highly personalized eyeglass or contact lens prescriptions.
- Time-Saving Efficiency
- Streamlined exams help your practice serve more patients without compromising accuracy, boosting overall productivity in [Specific Location].
- Enhanced Patient Experience
- Clear explanations and visual mapping engage patients and build trust, strengthening relationships and loyalty.
- Competitive Differentiation
- Staying ahead of the curve with leading-edge technology sets your practice apart.
- Versatile Applications
- Suitable for all types of patients, including those with complex visual issues or unique eyewear needs.
FAQs
- Q: Can I integrate the ZEISS i.Profiler Plus with existing practice management software?
- A: Yes. The device supports multiple data transfer options, allowing easy integration with most systems.
- Q: Is the ZEISS i.Profiler Plus suitable for pediatric patients?
- A: Absolutely. The fast measurement and non-invasive approach make it comfortable for patients of all ages, including children.
- Q: Do I need special training to operate this device?
- A: While the system is user-friendly, ZEISS provides training resources to ensure you and your staff can operate it confidently.
- Q: How often does the device require maintenance or calibration?
- A: Routine checks are recommended, but the ZEISS i.Profiler Plus is designed for long-term stability. Consult ZEISS guidelines for calibration intervals.
- Q: Does this device require a specific room setup?
- A: The ZEISS i.Profiler Plus has a relatively small footprint. Ensure a stable power supply and adequate space for comfortable patient positioning.
Reviews
There are no reviews yet.