{"id":3494,"date":"2017-08-01T06:25:27","date_gmt":"2017-08-01T06:25:27","guid":{"rendered":"https:\/\/www.navaophthalmic.com\/product\/icare-ic100-tonometer\/"},"modified":"2026-06-12T19:18:50","modified_gmt":"2026-06-12T19:18:50","slug":"icare-ic100-tonometer","status":"publish","type":"product","link":"https:\/\/navaophthalmic.com\/nl\/product\/icare-ic100-tonometer\/","title":{"rendered":"Icare ic100 Tonometer voor Glaucoombeheer"},"content":{"rendered":"<p style=\"text-align: justify;\">Icare ic100 Tonometer is a user-friendly <strong><a href=\"https:\/\/navaophthalmic.com\/handheld-tonometers\/\">handheld tonometer<\/a><\/strong> that allows all eye care professionals to obtain consistent, repeatable IOP measurements.<\/p>\n<p>The Icare ic100 Tonometer has a lightweight probe that makes momentary contact with the cornea. It also uses patented rebound technology to measure intraocular pressure.<\/p>\n<p>The <strong>iCare IC100 Tonometer<\/strong> is a specialized medical device used in eye care to measure the eye&#8217;s intraocular pressure (IOP). Accurate measurement of IOP is crucial for diagnosing and managing glaucoma, a group of eye conditions that can lead to optic nerve damage and vision loss if not properly managed.<\/p>\n<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }<\/style>\n<div class=\"embed-container\"><iframe src=\"https:\/\/www.youtube.com\/embed\/KnfioF_lGTI\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><strong>Key Features:<\/strong><\/h2>\n<ul>\n<li style=\"text-align: justify;\">The ability to be used without calibration, eye drops, air, or special training.<\/li>\n<li style=\"text-align: justify;\">Intelligent positioning. Red and green lights help operators guide the tonometer into the correct position for testing.<\/li>\n<li style=\"text-align: justify;\">Optometrists can load, align and measure.<\/li>\n<li style=\"text-align: justify;\">An automated measuring sequence, which takes a series of six measurements with one touch.<\/li>\n<\/ul>\n<div class=\"flex max-w-full flex-col flex-grow\">\n<div class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"54921d1a-8f66-458a-9ddb-d1ba98abb151\" data-message-model-slug=\"o1-mini\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\">\n<div class=\"markdown prose w-full break-words dark:prose-invert dark\">\n<h3><strong>Uses of the iCare IC100 Tonometer<\/strong><\/h3>\n<ul>\n<li><strong>Measuring Intraocular Pressure (IOP):<\/strong> The primary function is to assess the pressure within the eye, which is a critical factor in diagnosing and monitoring glaucoma.<\/li>\n<li><strong>Glaucoma Screening and Management:<\/strong> Regular IOP measurements help in the early detection of glaucoma and in monitoring the effectiveness of treatments to lower eye pressure.<\/li>\n<li><strong>Research and Clinical Studies:<\/strong> The device is also utilized in various clinical settings and research studies focusing on ocular health.<\/li>\n<\/ul>\n<h3><strong>Who Uses the iCare IC100 Tonometer?<\/strong><\/h3>\n<ul>\n<li><strong>Ophthalmologists:<\/strong> Medical doctors specializing in eye and vision care use the IC100 for comprehensive eye examinations and glaucoma management.<\/li>\n<li><strong>Optometrists:<\/strong> Eye care professionals who provide primary vision care also employ the IC100 for routine eye pressure assessments.<\/li>\n<li><strong>Opticians and Eye Care Technicians:<\/strong> In some settings, trained technicians may use the device under the supervision of eye care specialists.<\/li>\n<\/ul>\n<h3><strong>Why Must It Be Used?<\/strong><\/h3>\n<ul>\n<li><strong>Early Detection of Glaucoma:<\/strong> Elevated IOP is a significant risk factor for glaucoma. Regular monitoring can lead to early detection, allowing timely intervention to prevent vision loss.<\/li>\n<li><strong>Monitoring Treatment Efficacy:<\/strong> For patients diagnosed with glaucoma, the IC100 helps in assessing how well treatments (medications, laser therapy, or surgery) are controlling eye pressure.<\/li>\n<li><strong>Non-Invasive and Patient-Friendly:<\/strong> The rebound tonometry method used by the IC100 is less invasive and more comfortable than traditional tonometry techniques, enhancing patient compliance with regular check-ups.<\/li>\n<\/ul>\n<h3><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-5054\" src=\"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/Icare-IC-100-Tonometer-1024x614.jpg\" alt=\"iCare IC100 Tonometer\" width=\"900\" height=\"540\" srcset=\"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/Icare-IC-100-Tonometer-1024x614.jpg 1024w, https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/Icare-IC-100-Tonometer-300x180.jpg 300w, https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/Icare-IC-100-Tonometer-768x461.jpg 768w, https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/Icare-IC-100-Tonometer-570x342.jpg 570w, https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/Icare-IC-100-Tonometer.jpg 1500w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/strong><\/h3>\n<h3><strong>Explaining to Doctors vs. Patients<\/strong><\/h3>\n<h4><strong>For Doctors:<\/strong><\/h4>\n<p>The iCare IC100 Tonometer offers a reliable and efficient method for measuring IOP without topical anesthetics. Its portability and ease of use make it suitable for both clinical and field settings. The device&#8217;s rebound tonometry accurately measures various IOP levels, facilitating effective glaucoma screening and ongoing management. Its quick operation can enhance patient throughput without compromising accuracy, making it a valuable tool in ophthalmic and optometric practices.<\/p>\n<h4><strong>For Patients:<\/strong><\/h4>\n<p>The iCare IC100 is a device your eye doctor uses to check the pressure inside your eyes. This measurement is important because high eye pressure can lead to glaucoma, which can cause vision loss if not treated. Using the IC100 is quick and doesn&#8217;t require any numbing drops, so it&#8217;s more comfortable for you. Regular eye pressure checks with this device help catch any issues early, allowing your doctor to take steps to protect your vision.<\/p>\n<h3><strong>Benefits of the iCare IC100 Tonometer<\/strong><\/h3>\n<ul>\n<li><strong>Non-Invasive:<\/strong> Eliminates the need for anesthetic drops, reducing discomfort and simplifying the procedure.<\/li>\n<li><strong>Portable and Lightweight:<\/strong> Easy to move between examination rooms or use in various clinical settings.<\/li>\n<li><strong>Quick Measurements:<\/strong> Enhances efficiency in busy clinical environments by providing rapid IOP readings.<\/li>\n<li><strong>User-Friendly Interface:<\/strong> Simplifies the process for clinicians, allowing for straightforward operation and interpretation of results.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h3><strong>iCare IC100 Tonometer Technical Data<\/strong><\/h3>\n<table width=\"727\">\n<tbody>\n<tr>\n<td>MODEL NAME<\/td>\n<td>TA011<\/td>\n<\/tr>\n<tr>\n<td>DIMENSIONS<\/td>\n<td>24 \u2013 29 mm (W) * 35 \u2013 95 mm (H) * 215 mm (L)<\/td>\n<\/tr>\n<tr>\n<td>WEIGHT<\/td>\n<td>140 g (without batteries), 230 g (4 x AA batteries)<\/td>\n<\/tr>\n<tr>\n<td>POWER SUPPLY<\/td>\n<td>4 x AA non-rechargeable batteries, 1.5V alkaline LR6<\/td>\n<\/tr>\n<tr>\n<td>MEASUREMENT RANGE<\/td>\n<td>7-50 mmHg<\/td>\n<\/tr>\n<tr>\n<td>ACCURACY<\/td>\n<td>+\u00b11.2 mmHg (\u226420 mmHg) and \u00b12.2 mmHg (&gt;20 mmHg)<\/td>\n<\/tr>\n<tr>\n<td>REPEATABILITY<\/td>\n<td>&lt; 8 % (coefficient of variation)<\/td>\n<\/tr>\n<tr>\n<td>ACCURACY OF DISPLAY<\/td>\n<td>1 mmHg<\/td>\n<\/tr>\n<tr>\n<td>DISPLAY UNIT<\/td>\n<td>Millimeter of mercury (mmHg)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 style=\"text-align: justify;\"><strong>Include<\/strong><\/h3>\n<ul>\n<li><strong>Icare ic100<\/strong> Tonometer<\/li>\n<li>4 x AA batteries<\/li>\n<li>100 single use probes in a box<\/li>\n<li>aluminum case<\/li>\n<li>IOP pad<\/li>\n<li>probe base cleaning container<\/li>\n<li>probe base plug<\/li>\n<li>quick guide<\/li>\n<li>screw driver<\/li>\n<li>silicone grip<\/li>\n<li>spare probe base<\/li>\n<li>USB memory stick including instruction manuals<\/li>\n<li>warranty card<\/li>\n<li>wrist strap<\/li>\n<\/ul>\n<p>The iCare IC100 Tonometer is a valuable tool in eye care, offering a combination of accuracy, comfort, and efficiency in measuring intraocular pressure. Its use is essential for effectively diagnosing and managing glaucoma, helping prevent vision loss and maintain ocular health. Whether you are a healthcare professional or a patient, understanding the role and benefits of the IC100 can contribute to better eye health outcomes.<\/p>\n<p style=\"text-align: justify;\"><a href=\"http:\/\/www.icaretonometer.com\/products\/icare-ic100\/\"><strong>Icare ic100 Tonometer Manufacturer Information<\/strong><\/a><\/p>\n<p style=\"text-align: justify;\">\n","protected":false},"excerpt":{"rendered":"<p>U kunt de iCare IC100 Tonometer bekijken, een draagbaar, niet-invasief apparaat voor nauwkeurige meting van de intraoculaire druk (IOP). Ideaal voor oogartsen en optometristen, het vergemakkelijkt de vroege detectie van glaucoom en effectief oogzorgmanagement.<\/p>","protected":false},"featured_media":3492,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[554],"product_tag":[],"class_list":["post-3494","product","type-product","status-publish","has-post-thumbnail","product_cat-tonometer","first","instock","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.7 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Icare ic100 Tonometer For Sale<\/title>\n<meta name=\"description\" content=\"Icare ic100 Tonometer is user-friendly handheld tonometer to obtain consistent, repeatable IOP measurements for all eye care professionals\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/navaophthalmic.com\/nl\/product\/icare-ic100-tonometer\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Icare ic100 Tonometer for Glaucoma Management\" \/>\n<meta property=\"og:description\" content=\"Icare ic100 Tonometer is user-friendly handheld tonometer to obtain consistent, repeatable IOP measurements for all eye care professionals\" \/>\n<meta property=\"og:url\" content=\"https:\/\/navaophthalmic.com\/nl\/product\/icare-ic100-tonometer\/\" \/>\n<meta property=\"og:site_name\" content=\"Nava Ophthalmic\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-12T19:18:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/580-Icare-ic100-Tonometer.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Prijs\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;1,550.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"Beschikbaarheid\" \/>\n\t<meta name=\"twitter:data2\" content=\"Op voorraad\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"ItemPage\"],\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/\",\"url\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/\",\"name\":\"Icare ic100 Tonometer For Sale\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/navaophthalmic.com\\\/wp-content\\\/uploads\\\/2017\\\/08\\\/580-Icare-ic100-Tonometer.jpg\",\"datePublished\":\"2017-08-01T06:25:27+00:00\",\"dateModified\":\"2026-06-12T19:18:50+00:00\",\"description\":\"Icare ic100 Tonometer is user-friendly handheld tonometer to obtain consistent, repeatable IOP measurements for all eye care professionals\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/navaophthalmic.com\\\/wp-content\\\/uploads\\\/2017\\\/08\\\/580-Icare-ic100-Tonometer.jpg\",\"contentUrl\":\"https:\\\/\\\/navaophthalmic.com\\\/wp-content\\\/uploads\\\/2017\\\/08\\\/580-Icare-ic100-Tonometer.jpg\",\"width\":1000,\"height\":900,\"caption\":\"Icare ic100\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/product\\\/icare-ic100-tonometer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/navaophthalmic.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Shop\",\"item\":\"https:\\\/\\\/navaophthalmic.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Icare ic100 Tonometer for Glaucoma Management\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/#website\",\"url\":\"https:\\\/\\\/navaophthalmic.com\\\/\",\"name\":\"Nava Ophthalmic\",\"description\":\"Largest optometric supplies of ophthalmic products\",\"publisher\":{\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/navaophthalmic.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/#organization\",\"name\":\"Nava Ophthalmic Ltd\",\"url\":\"https:\\\/\\\/navaophthalmic.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/navaophthalmic.com\\\/wp-content\\\/uploads\\\/2018\\\/02\\\/logo.png\",\"contentUrl\":\"http:\\\/\\\/navaophthalmic.com\\\/wp-content\\\/uploads\\\/2018\\\/02\\\/logo.png\",\"width\":256,\"height\":192,\"caption\":\"Nava Ophthalmic Ltd\"},\"image\":{\"@id\":\"https:\\\/\\\/navaophthalmic.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"description\":\"Nava Ophthalmic features largest optometric supplies of ophthalmic products, and the purpose of our existence offers the optimal quality service in favor of ophthalmology, and we are fully committed towards our whole purpose. We are not just another company neither we make false promises. Instead, we prove what we claim.\",\"email\":\"sales@navaophthalmic.com\",\"telephone\":\"+65 6514 0888\",\"legalName\":\"Nava Ophthalmic\",\"foundingDate\":\"2002-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"51\",\"maxValue\":\"200\"}}]}<\/script>\n<meta property=\"product:price:amount\" content=\"1550.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:retailer_item_id\" content=\"Icare ic100\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Icare ic100 Tonometer te koop","description":"De Icare ic100 Tonometer is een gebruiksvriendelijke handheld tonometer om consistente, reproduceerbare IOP-metingen te verkrijgen voor alle oogzorgprofessionals","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/navaophthalmic.com\/nl\/product\/icare-ic100-tonometer\/","og_locale":"nl_NL","og_type":"article","og_title":"Icare ic100 Tonometer for Glaucoma Management","og_description":"Icare ic100 Tonometer is user-friendly handheld tonometer to obtain consistent, repeatable IOP measurements for all eye care professionals","og_url":"https:\/\/navaophthalmic.com\/nl\/product\/icare-ic100-tonometer\/","og_site_name":"Nava Ophthalmic","article_modified_time":"2026-06-12T19:18:50+00:00","og_image":[{"width":1000,"height":900,"url":"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/580-Icare-ic100-Tonometer.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Prijs":"&#36;1,550.00","Beschikbaarheid":"Op voorraad"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","ItemPage"],"@id":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/","url":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/","name":"Icare ic100 Tonometer te koop","isPartOf":{"@id":"https:\/\/navaophthalmic.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/#primaryimage"},"image":{"@id":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/#primaryimage"},"thumbnailUrl":"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/580-Icare-ic100-Tonometer.jpg","datePublished":"2017-08-01T06:25:27+00:00","dateModified":"2026-06-12T19:18:50+00:00","description":"De Icare ic100 Tonometer is een gebruiksvriendelijke handheld tonometer om consistente, reproduceerbare IOP-metingen te verkrijgen voor alle oogzorgprofessionals","breadcrumb":{"@id":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/#primaryimage","url":"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/580-Icare-ic100-Tonometer.jpg","contentUrl":"https:\/\/navaophthalmic.com\/wp-content\/uploads\/2017\/08\/580-Icare-ic100-Tonometer.jpg","width":1000,"height":900,"caption":"Icare ic100"},{"@type":"BreadcrumbList","@id":"https:\/\/navaophthalmic.com\/product\/icare-ic100-tonometer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/navaophthalmic.com\/"},{"@type":"ListItem","position":2,"name":"The Shop","item":"https:\/\/navaophthalmic.com\/shop\/"},{"@type":"ListItem","position":3,"name":"Icare ic100 Tonometer for Glaucoma Management"}]},{"@type":"WebSite","@id":"https:\/\/navaophthalmic.com\/#website","url":"https:\/\/navaophthalmic.com\/","name":"Nava Ophthalmic","description":"Grootste optometri\u00eble leveranciers van oogheelkundige producten","publisher":{"@id":"https:\/\/navaophthalmic.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/navaophthalmic.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/navaophthalmic.com\/#organization","name":"Nava Ophthalmic Ltd","url":"https:\/\/navaophthalmic.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/navaophthalmic.com\/#\/schema\/logo\/image\/","url":"http:\/\/navaophthalmic.com\/wp-content\/uploads\/2018\/02\/logo.png","contentUrl":"http:\/\/navaophthalmic.com\/wp-content\/uploads\/2018\/02\/logo.png","width":256,"height":192,"caption":"Nava Ophthalmic Ltd"},"image":{"@id":"https:\/\/navaophthalmic.com\/#\/schema\/logo\/image\/"},"description":"Nava Ophthalmic beschikt over de grootste optometric leverancier van oogheelkundige producten, en het doel van ons bestaan is het bieden van optimale kwaliteitsdienstverlening ten gunste van de oogheelkunde, en wij zetten ons volledig in voor ons hele doel. Wij zijn niet zomaar een bedrijf en we doen geen valse beloften. In plaats daarvan bewijzen we wat we beweren.","email":"sales@navaophthalmic.com","telephone":"+65 6514 0888","legalName":"Nava Ophthalmic","foundingDate":"2002-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"51","maxValue":"200"}}]},"product_price_amount":"1550.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_retailer_item_id":"Icare ic100","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/product\/3494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/comments?post=3494"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/media\/3492"}],"wp:attachment":[{"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/media?parent=3494"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/product_brand?post=3494"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/product_cat?post=3494"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/navaophthalmic.com\/nl\/wp-json\/wp\/v2\/product_tag?post=3494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}